Oil and Gas

UMD™ systems utilize proven and field tested uninterruptible power supply principles that achieve unmatched reliability.

Achieve unmatched reliability for critical rotating equipment such as pumps and fans!

Compressor stations’ and extraction plants’ reliability and availability are important to overall pipeline delivery dependability. Therefore, 100% availability and reliability are essential for critical auxiliary systems or rotating equipment such as pumps, fans, and other loads.

AC UPS and DC Motor based-backup systems are not suitable or reliable backup solutions for rotating loads. KraftPowercon’s Uninterruptible Motor Drives solution UMD™ is the most effective solution to secure motor loads and other static loads.

Full availability

Eliminates Single Point of Failure

Complete factory tested system

UMD™ is the most reliable way to power your motor

Supplying motors with the correct power during critical operation means the difference between profit and downtime costs, the difference between running machines and mechanical failures, and the difference between planning ahead and planning urgent field service.

UMD™ systems utilize proven and field tested uninterruptible power supply principles that achieve unmatched reliability.

Full availability

UMD™ provides continuous operation of 3-phase AC motors, with no interruption during utility power disturbances. In normal operation the Variable Frequency Drive (VFD) is supplied from mains. During a brown out or mains outage the VFD is powered from a battery connected directly to the DC-bus of the VFD. The transition between the power sources is completely seamless, meaning no speed drop during any disturbances of the mains supply.

Eliminates Single Point of Failure

The UMD™ system is designed to remove all Single Points of Failure. Traditional UPS systems must be doubled or excessively oversized to achieve the same safety level.

Complete factory tested UMD™ system

UMD™ is delivered as one complete MCC-unit. Type tested according to IEC, UL, CSA and other applicable standards. The system has single or redundant mains input breakers, battery charger, AC and DC busbars, and the required motor drive outputs. In addition, it can be extended to backup all AC and DC auxiliary loads. As a result of this several complex engineering activities including battery sizing, power loss calculations, motor protection settings, fuse selectivity in distribution board, can be eliminated. It also allows for fast and straightforward installation and commissioning that can be performed by local technicians.

Oil and Gas

Our Uninterruptible Power Systems Experts

David Persson - +46(0)470 705 200

Peter Knutsson - +46(0)470 705 200

Arvid Mårtensson - +46(0)470 705 200

Contact us about everything Uninterruptible Power Systems at:
ups@kraftpowercon.com

Our latest posts on LinkedIn

Stay up to date with everything KraftPowercon Uninterruptible Power Systems